Hach SIGMA 900 Manual de usuario

Busca en linea o descarga Manual de usuario para Cargadores de batería de coche Hach SIGMA 900. Hach SIGMA 900 User's Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir

Indice de contenidos

Pagina 1 - Sigma 900 Composite Sampler

Catalog Number 8544 Sigma 900 Composite SamplerINSTRUMENT MANUAL© Hach Company, 2003. All rights reserved. Printed in the U.S.A. eac 07/03 2ed

Pagina 2 - Visit http: //www.hach.com

Page 10 Safety Information8544intro.fmSection 22.4.1 Use of Hazard InformationIf multiple hazards exist, this manual will use the signal word (Danger,

Pagina 3 - Table of Contents

Section 2Page 11 8544intro.fm Safety InformationDANGERBien que certains produits Hach soient conçus et certifiés pour être installés dans des endroits

Pagina 4

Page 12 Safety Information8544intro.fmSection 22.4.5 Definition of Confined SpaceA Confined Space is any location or enclosure that presents or has th

Pagina 5 - Section 1 Specifications

Page 13 8544install.fm InstallationSection 3 InstallationDANGER Only qualified personnel should conduct the installation tasks described in this secti

Pagina 6

Page 14 Mounting the Sampler8544install.fmSection 3Figure 4 Wall Mount Bracket 3.3 Mounting the SamplerAttach the wall mount bracket to a stable panel

Pagina 7 - Section 2 General Information

Section 3Page 15 8544install.fm Setting Up the Intake Line and Strainer4. Slide the tubing clamp over the silicone tubing until it is over the stainle

Pagina 8 - 2.3 Front Panel

Page 16 Power Connections8544install.fmSection 3Figure 5 Full Bottle Shut-off3.8 Power ConnectionsThe sampler controller operated on 12 V dc which is

Pagina 9 - 2.4 Safety Information

Section 3Page 17 8544install.fm 12 V dc• Before performing any maintenance, disconnect the sampler from the power source.• Do not attempt to make any

Pagina 10 - Section 2

Page 18 Auxiliary Connection8544install.fmSection 3Contact ClosuresThe sampler controller is capable of accumulating 1 to 9999 contact closures. Each

Pagina 11

Section 3Page 19 8544install.fm Auxiliary ConnectionFigure 6 4–20 mA Interface and Pulse Duration InputFor details on programming the sampler for flow

Pagina 12

Visit http: //www.hach.com

Pagina 13 - Section 3 Installation

Visit http: //www.hach.com

Pagina 14 - 3.4 Attaching the Intake Line

Page 21 8544operations.fm OperationSection 4 Operation4.1 Keypad and Key FunctionsFigure 8 shows the 18-position keypad and 24-character alphanumeric

Pagina 15 - 3.6 Choosing Bottles

Page 22 Tips and Techniques for Programming the Instrument8544operations.fmSection 4Figure 8 Front Panel4.2 Tips and Techniques for Programming the In

Pagina 16 - 3.8 Power Connections

Section 4Page 23 8544operations.fm Setting the Time and Date4.3 Setting the Time and DateBefore programming the sampler for the first time, check the

Pagina 17 - 3.9 12 V dc

Page 24 Explanations of Program Messages8544operations.fmSection 44.5 Explanations of Program MessagesItem NumberMessage Description of Message1 READY

Pagina 18

Section 4Page 25 8544operations.fm Data Logging4.6 Data LoggingThe sampler records the time and date that each sample was collected, up to 400 samples

Pagina 19

Page 26 Measurements Triggered by Liquid Levels or Flow8544operations.fmSection 45. To exit the manual mode, press CLEAR ENTRY. This returns the sampl

Pagina 20

Section 4Page 27 8544operations.fm Programming the Sampler for Level Control4.9 Programming the Sampler for Level ControlPut the sampler in a standby

Pagina 21 - Section 4 Operation

Page 28 Flow Proportional Operation8544operations.fmSection 44.11 Flow Proportional Operation4.11.1 How to Calculate Pulses/Counts4.11.1.1 Flow Propor

Pagina 22 - Section 4

Section 4Page 29 8544operations.fm Flow Proportional Operation1. Determine the flow increment between samples:2. Multiply the flow increment, f, by th

Pagina 23 - * key causes the display to

Page 3 8544TOC.fm Table of ContentsTable of ContentsSection 1 Specifications...

Pagina 24

Page 30 Flow Proportional Operation8544operations.fmSection 4Use the following examples to help you determine the value that you need to enter when pr

Pagina 25 - 4.7 Manual Mode

Section 4Page 31 8544operations.fm Flow Proportional Operation2. Calculate t.3. Multiply Q x t. Therefore, the value entered for INTV = _ _ _ _ CNTS

Pagina 26

Visit http: //www.hach.com

Pagina 27 - 4.10 Other Displayed Messages

Page 33 8544Maintenance.fm MaintenanceSection 5 MaintenanceDANGER Only qualified personnel should conduct the installation tasks described in this sec

Pagina 28

Page 34 Re-installing the Bottom Panel8544Maintenance.fmSection 54. Place the controller, face down, on a cloth-covered workbench to prevent scratchin

Pagina 29

Section 5Page 35 8544Maintenance.fm Internal Desiccant Module5.8 Internal Desiccant ModuleThe Internal Desiccant Module (Cat. No. 787) consists of a m

Pagina 30

Page 36 Motor/Gear Box8544Maintenance.fmSection 55.10 Motor/Gear BoxThe motor/gear box requires no regular maintenance. The special formulation gears

Pagina 31

Contact Information for U.S.A. & Outside Europe Page 37Section 6 Contact Information for U.S.A. & Outside EuropeOrdering Information for the U

Pagina 32

Contact Information for Europe Page 38Section 7 Contact Information for EuropeFor technical support, repair service, and ordering information please r

Pagina 33 - Section 5 Maintenance

Limited Warranty Page 39Section 8 Limited WarrantyHach Company warrants its products to the original purchaser against any defects that are due to fau

Pagina 34 - Section 5

Page 4 Table of Contents8544TOC.fmTable of ContentsSection 5 Maintenance ...

Pagina 36 - 5.13 Memory Battery

Page 41 8544parts.fm Parts and AccessoriesSection 9 Parts and AccessoriesDescription Part Number3-way Splitter Assembly...

Pagina 37 - Repair Service

Visit http: //www.hach.com

Pagina 38

Page 43 8544apdx_pulsecounts.fm Programming Flow ChartAppendix A Programming Flow ChartProgram Flow ChartReady to Start Program Halted Program Complet

Pagina 39 - Section 8 Limited Warranty

Visit http: //www.hach.com

Pagina 40 - Visit us at www.hach.com

Page 45 8544apdx_batteries.fm Batteries and ChargersAppendix B Batteries and ChargersLead-Acid (Gel Cell) BatteriesLead-acid batteries are designed to

Pagina 41

Page 46 Batteries and Chargers8544apdx_batteries.fmAppendix BNickel-Cadmium BatteriesNickel-cadmium batteries provide superior power capabilities when

Pagina 42

Page 47 8544apdx_engdraw.fm Exploded View DrawingsAppendix C Exploded View DrawingsExploded View (1 of 6)Item Number Description QTY Part Number1 Pump

Pagina 43 - Program Flow Chart

Page 48 Exploded View Drawings8544apdx_engdraw.fmAppendix CExploded View (2 of 6)Item Number Description QTY Part Number1 Latch 1 22792 Keypad Cable A

Pagina 44

Appendix CPage 49 8544apdx_engdraw.fm Exploded View DrawingsExploded View (3 of 6)Item NumberDescription QTYPart NumberItem NumberDescription QTYPart

Pagina 45 - Storage Time (months)

Page 5 8544specs.fm SpecificationsSection 1 SpecificationsSpecifications are subject to change without notice.Controller DimensionsHeight: 34 cm (13.5

Pagina 46 - Nickel-Cadmium Batteries

Page 50 Exploded View Drawings8544apdx_engdraw.fmAppendix CExploded View (4 of 6)Item NumberDescription QTYPart NumberItem NumberDescription QTYPart N

Pagina 47 - Exploded View (1 of 6)

Appendix CPage 51 8544apdx_engdraw.fm Exploded View DrawingsExploded View (5 of 6)Item NumberDescription QTYPart NumberItem NumberDescription QTYPart

Pagina 48 - Exploded View (2 of 6)

Page 52 Exploded View Drawings8544apdx_engdraw.fmAppendix CExploded View (6 of 6)Item Number Description Part Number1 CPU PCB Assembly 89212 Distribut

Pagina 49 - Exploded View (3 of 6)

Visit http: //www.hach.com

Pagina 50 - Exploded View (4 of 6)

Page 7 8544intro.fm General InformationSection 2 General Information2.1 Instrument DescriptionThe instrument is designed to automatically collect and

Pagina 51 - Exploded View (5 of 6)

Page 8 Front Panel8544intro.fmSection 2Figure 1 Interface Connectors 2.3 Front Panel The front panel consists of the keypad, liquid crystal display, a

Pagina 52 - Exploded View (6 of 6)

Section 2Page 9 8544intro.fm Safety InformationFigure 2 900 Composite Sampler2.4 Safety InformationPlease read this entire manual before unpacking, se

Comentarios a estos manuales

Sin comentarios